Quote Mail Chat in

DZ-6M/LDZ-6M Electromagnetic Switch

يشارك
وي شات
نسخ الوصلة
فيسبوك
X
ينكدين
Whatsapp
DKLD DZ-6 provides stable motor control performance for woodworking machinery, concrete mixers, small machine tools and industrial equipment. Designed as a reliable alternative solution for KJD17 type applications.
معامل
Model
:
DZ-6
Standard
:
TUV/CE CE(EN61058 EN60947)
Rated Voltage
:
250V~/110V~
Rated Current
:
16(15A AC-3:15A
Max ambient temperature
:
T85/T55
Level of protection
:
IP55
Number of operating cycles
:
5E4
Enquiry
Detail
Why DZ-6

Protection built into the switch

The DZ-6 series is a double-pole, normally open electromagnetic switch with power-loss and undervoltage protection — designed for machinery that must not restart on its own.

Power-loss & undervoltage protection

The main circuit opens automatically when power fails or voltage drops below the rated level.

Restart protection

After power returns, the machine stays off until the start button is pressed again — no unexpected start-ups.

Built to last

Longer service life, higher current rating and better sealing, protected by national utility-model and design patents.

External protection-loop terminals

Wire an overload relay, travel switch, thermostat or Hall switch into one integrated protection loop.

Specifications

DZ-6 vs LDZ-6

Two certification lines of the same switch: the DZ-6 carries CE / TÜV approval for 250 V~ markets, while the LDZ-6 carries UL 61058 approval for 127 V~ markets.

SpecificationDZ-6LDZ-6
DescriptionDouble-pole normally open, with power-loss and undervoltage protectionDouble-pole normally open, with power-loss and undervoltage protection
CertificationEN / IEC 60947-3 · EN 61058-1 T85 · CE · TÜVUL 61058
Rated voltage250 V~ / 110 V~127 V~
Rated current16(15) A18(18) A
AC-3 250 V15 A—
AC-15 250 V8 A—
Enclosure protectionIP55IP55
Max ambient temperatureT85/55T85/55
Mechanical life50,000 cycles50,000 cycles
Wiring versions

4P and 5P wiring

Both versions are double-pole make with an undervoltage release coil (U<). The 5P version adds the A1 control terminal for wiring external protection devices into the loop.

DZ-6 / LDZ-6 technical drawing — 4P and 5P switch renders, wiring diagrams showing OUT / IN and terminals 3 4 7 8 (+ A1), and dimension drawingsElectromagnetic Switch DZ06 KJD17 Diagram (2).png
Official DZ-6 / LDZ-6 drawing: 4P and 5P wiring diagrams (OUT / IN, O / I, terminals 3 · 4 · 7 · 8, + A1) with dimensional drawings.
4P

Terminals 3 · 4 · 7 · 8 — double-pole make with undervoltage release.

5P

Terminals 3 · 4 · 7 · 8 + A1 (2.8 mm) — A1 for external protection-loop wiring.

Mounting

Panel cutout 46 × 22 mm; fast-on terminals 6.3 mm.

Applications

Built for Motor-Driven Machinery

The DZ6 starts and controls motors on machines that must stop safely when power fails — and stay stopped until an operator restarts them.

01

Woodworking machinery

Saws, jointers, planers and sanders

02

Bench drills

Benchtop drilling machines

03

Tile & wet cutters

Water-cooled tile saws and cutters

04

Small machine tools

Lathes, mills and grinders

05

Mixers

Concrete and food mixers

06

Garden machinery

Chippers, shredders and yard equipment

Also used in electric drive control equipment.

Company

Made by Yue Qing Dongke Electric Co., Ltd.

A switch manufacturer with UL- and TÜV-certified in-house laboratories and over two decades of supply to leading power-tool brands.

2003
Since
30,000 m²
Plant
100+
Patents
ISO 9001:2015
Quality

DKLD designs and manufactures electromagnetic switches, speed-control switches and protection devices for electric appliances. Products are approved under TUV, UL, CE, AS, FDA and SAA, with more than 100 national patents — and ship to customers including Black & Decker and TTI.

CETÜVUL 61058EN / IEC 60947-3EN 61058-1IP55
DKLD factory complex — multi-storey production plant of Yue Qing Dongke Electric Co., Ltd.
30,000 m² plant · Hongqiao Town, Leqing, Wenzhou, Zhejiang, China

FAQ

What is the DZ-6M / LDZ-6M electromagnetic switch?

It is a double-pole, normally open electromagnetic switch with power-loss and undervoltage protection. When power fails or the voltage drops below the rated level, the main circuit opens automatically, and after power returns the machine stays off until the start button is pressed again (restart protection).

What is the DZ-6M / LDZ-6M used for?

It starts and controls motors on machinery that must stop safely when power fails. Typical applications are woodworking machinery such as saws, jointers, planers and sanders, bench drills, tile and wet cutters, small machine tools such as lathes, mills and grinders, mixers, garden machinery and electric drive control equipment.

What certifications and standards does the DZ-6 / LDZ-6 carry, and who manufactures it?

The DZ-6 carries TUV/CE CE(EN61058 EN60947), and the LDZ-6 line is approved to EN / IEC 60947-3, EN 61058-1 T85, UL 61058, CE and T�V; the DZ-6 is the certification line for 250V~ markets and the LDZ-6 the line for 127 V~ markets. It is manufactured by Yue Qing Dongke Electric Co., Ltd. (DKLD) in a 30,000 m� plant in Wenzhou, Zhejiang, with UL- and T�V-certified in-house laboratories.

What are the main technical data of the DZ-6M / LDZ-6M?

The DZ-6 line is rated 250V~/110V~ with a rated current of 16(15A AC-3:15A, a maximum ambient temperature class of T85/T55 and protection level IP55. The LDZ-6 line is rated 127 V~ with 16(15) A and 18(18) A (AC-3 250 V 15 A, AC-15 250 V 8 A), T85/55 and the same IP55 protection, and mechanical life is 50,000 cycles.

How is the DZ-6M / LDZ-6M installed and wired?

Both versions are double-pole make with an undervoltage release coil (U<). The 4P version uses terminals 3 � 4 � 7 � 8, while the 5P version adds the A1 control terminal (2.8 mm) for wiring external protection devices into the loop. Mounting uses a panel cutout of 46 � 22 mm with fast-on terminals of 6.3 mm.

Can the DZ-6 / LDZ-6 be used in KJD17 type applications?

It is designed as a reliable alternative solution for KJD17 type applications, with a higher current rating, longer service life and better sealing, protected by national utility-model and design patents. An overload relay, travel switch, thermostat or Hall switch can be wired into one integrated protection loop through the external protection-loop terminals.

Quick Enquiry

  • Full Name*

  • Company

  • Email*

  • Phone / WhatsApp*

  • Subject*

  • Message*

Ivy:Whatsapp
Paul:Whatsapp