Quote Mail in

DZ-6 & DZ04-2 Electromagnetic Switches: KEDU KJD17 / KJD20 Drop-in Guide

2026-08-28 14:02

DZ-6 & DZ04-2 Electromagnetic Switches: Drop-in Replacements for KEDU KJD17 / KJD20

If your machines ship with KEDU KJD17 / KJD17B or KJD20 electromagnetic switches — a concrete mixer, a wood chipper, an industrial shredder or a food processing machine — this technical application guide from DKLD Dongke Electric explains how the DZ-6 and DZ04-2 families give you a qualification-ready alternative that adds restart prevention and an integrated emergency stop within the same footprint class.

Direct answer: Yes — DKLD's DZ-6 series is an application-compatible alternative for the KEDU KJD series (e.g. KJD17/KJD17B) of electromagnetic switches, and the DZ04-2 covers KJD20-style applications. The DZ-6-2M delivers double-pole electromagnetic motor control with emergency stop (ISO 13850), power-loss restart prevention and undervoltage protection in an IP55 enclosure, certified TÜV/CE (EN 61058, EN 60947); the LDZ-6-2M variant carries UL 61058 (cRUus) for North America.

Key Points

  • Positioning: DZ-6-2M / LDZ-6-2M cover the KJD17 / KJD17B application slots; DZ04-2 covers KJD20-style applications; DZ08-2D4 / DZ08-4C6 are positioned for KEDU KOA-family switches.
  • Safety by design: integrated self-locking emergency stop (ISO 13850 / IEC 60947-5-5), power-loss & undervoltage protection, and no-unexpected-restart behavior per EN 60204-1 — no separate panel-mount E-stop needed.
  • Harsh-environment rated: IP55 high-strength thermoplastic housing with quick-on screw terminals — sealed against cement dust, wood chips, paper dust and splash.
  • Dual certification: TÜV + CE (EN 61058, EN 60947) for Europe; cRUus (UL 61058) for North America — one switch family for both export channels.
  • External protection-loop terminals: wire an overload relay, travel switch, thermostat or Hall switch into one integrated protection loop.
  • Proven life: 50,000 mechanical cycles rated — qualification samples available for your own life-cycle test.

Series Positioning

KEDU seriesDKLD series alternativeNotes
KJD17 / KJD17BDZ-6-2M / LDZ-6-2MSame control class; adds E-stop + restart prevention
KJD20DZ04-2Series-matched alternative for KJD20 slots
KOA7 / KOA seriesDZ08-2D4 / DZ08-4C6DZ08 positioned for the KOA series

DZ-6-2M Technical Snapshot (Verified Product Data)

SpecificationDZ-6LDZ-6
CertificationTÜV + CE (EN 61058, EN 60947)cRUus (UL 61058)
Rated voltage250 V~ / 110 V~127 V~
Rated current16(15) A · AC-3: 15 A18(18) A
Temperature ratingT85 / T55T85 / T55
Enclosure protectionIP55IP55
Mechanical life50,000 cycles50,000 cycles
Pole configurationDouble-pole, normally openDouble-pole, normally open
Protection functionsPower-loss & undervoltage protectionSame
Safety featuresE-stop (ISO 13850 / IEC 60947-5-5), restart preventionSame

Qualification Checklist Before Switching a Machine Line

  1. Confirm electrical rating match: voltage (230/110 V), current (AC-3 duty) and frequency.
  2. Verify panel cutout and mounting dimensions against the incumbent switch's datasheet.
  3. Check wiring/terminal compatibility (quick-on screw terminals, wire gauge).
  4. Confirm certification scope covers your target market (TÜV/CE for EU, cRUus for US/Canada).
  5. Request samples and run your own life-cycle test on the machine's start/stop profile.
  6. For EU machines, confirm EN 60204-1 restart prevention compliance; update the machine's declaration of conformity with the new component's certificates.

One component family across your whole machine range — qualified for concrete mixers, wood chippers, shredders, food processing machines and machine tools, certified for both hemispheres. Ask DKLD for the datasheet and a sample.

Download the full DZ-6 / DZ04 Replacement Guide (PDF)

Need a custom solution? Contact our engineers →